1.
Microbiol Spectr ; 11(3): e0532422, 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: covidwho-2290750

RESUMO

Saliva is a promising alternative for a nasopharyngeal swab (NPS) in specimen collection to detect SARS-CoV-2. We compared the diagnostic performance and tolerability of saliva collection versus NPS in a clinical setting. Paired NPS and saliva specimens were collected sequentially from participants (n = 250) at the Turku University Hospital drive-in coronavirus testing station in the spring of 2022, with Omicron BA.2 as the dominant SARS-CoV-2 variant. Discomfort and preference for the sampling method were assessed. The specimens were analyzed for SARS-CoV-2 using real-time multiplex reverse transcriptase PCR (RT-PCR) with a laboratory-developed test (LDT) and two commercial kits (PerkinElmer SARS-CoV-2 and PerkinElmer SARS-CoV-2 Plus) for several target genes. Among the 250 participants, 246 had respiratory symptoms. With LDT, SARS-CoV-2 was detected in 135 and 134 participants from NPS and saliva, respectively. Of the 250 specimens, 11 gave a discordant outcome, resulting in excellent agreement between the specimen types (Cohen's kappa coefficient of 0.911; P = 0.763). The cycle threshold (CT) values of LDT and commercial kit target genes were significantly lower from NPS than from saliva. A total of 172 (69%) participants assessed saliva sampling as more tolerable than NPS (P < 0.0001). Our findings present saliva as an applicable alternative for SARS-CoV-2 diagnostics. However, the lower CT values obtained from NPS indicate that NPS may be a slightly more sensitive specimen type. Participants preferred saliva sampling, although delivering an adequate volume of saliva was challenging for some participants. IMPORTANCE The extensive testing of SARS-CoV-2 is vital in controlling the spread of COVID-19. The reference standard for specimen collection is a nasopharyngeal swab (NPS). However, the discomfort of NPS sampling, the risk of nosocomial infections, and global material shortages have accelerated the development of alternative testing methods. Our study demonstrates that patients tolerate saliva sampling better than NPS. Of importance, although the RT-PCR qualitative test results seem to correspond between NPS and saliva, we show significantly lower CT values for NPS, compared to saliva, thus contradicting the suggested superiority of the saliva specimen over NPS in the detection of the Omicron variants of SARS-CoV-2. Future research is still required to enable individual planning for specimen collection and to determine the effects of different SARS-CoV-2 variants on the sensitivity of the saliva matrix.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Saliva , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Teste para COVID-19 , Nasofaringe
2.
Microbiol Spectr ; 9(2): e0073621, 2021 10 31.
Artigo em Inglês | MEDLINE | ID: covidwho-1476398

RESUMO

The supply of testing equipment is vital in controlling the spread of SARS-CoV-2. We compared the diagnostic efficacy and tolerability of molded plastic (FinSwab; Valukumpu, Finland) versus flocked nylon (FLOQSwab; Copan, Italy) nasopharyngeal swabs in a clinical setting. Adults (n = 112) with suspected symptomatic COVID-19 infection underwent nasopharyngeal sampling with FinSwab and FLOQSwab from the same nostril at a drive-in coronavirus testing station. In a subset of 36 patients the samples were collected in a randomized order to evaluate the discomfort associated with sampling. SARS-CoV-2 and 16 other respiratory viruses, as well as human ß-actin mRNA were analyzed by using reverse transcriptase PCR (RT-PCR) assays. Among the 112 patients (mean age, 38 [standard deviation (SD), 14] years) ß-actin mRNA was found in all samples. There was no difference in the ß-actin mRNA cycle threshold (CT) values between FinSwab (mean, 22.3; SD, 3.61) and FLOQSwab (mean, 22.1; SD, 3.50; P = 0.46) swabs. There were 31 virus-positive cases (26 rhinovirus, 4 SARS-CoV-2, and 1 coronavirus-OC43), 24 of which were positive in both swabs; 3 rhinovirus positives were only found in the FinSwab, and similarly 4 rhinovirus positives were only found in the FLOQSwab. Rhinovirus CT values were similar between swab types. Of the 36 patients, 22 (61%) tolerated the sampling with the FinSwab better than with the FLOQSwab (P = 0.065). The molded plastic nasopharyngeal swab (FinSwab) was comparable to the standard flocked swab in terms of efficacy for respiratory virus detection and tolerability of sampling. IMPORTANCE We demonstrate that a molded plastic swab is a valid alternative to conventional brush-like swabs in collection of a nasopharyngeal sample for virus diagnostics.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Nasofaringe/virologia , SARS-CoV-2/isolamento & purificação , Manejo de Espécimes/instrumentação , Actinas/genética , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Plásticos , RNA Mensageiro/genética , Infecções Respiratórias/diagnóstico , Rhinovirus/isolamento & purificação , Manejo de Espécimes/métodos , Adulto Jovem